Description

An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages.

Metrics

CVSS 3.0 7.8/10CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 30, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-54429.8A Stack-based Buffer Overflow issue was discovered in Fuji Electric V-Server VPR 4.0.1.0 and prior. The stack-based buffer overflow vulnerabCVE-2018-54435.3A SQL Injection issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. WebAccess/SCADA does not properly sanitizCVE-2018-54455.3A Path Traversal issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. An attacker has read access to files witCVE-2018-54464.9Medtronic 2090 CareLink Programmer uses a per-product username and password that is stored in a recoverable format.CVE-2018-54479.8An Improper Input Validation issue was discovered in Nari PCS-9611 relay. An improper input validation vulnerability has been identified thaCVE-2018-54484.8Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker tCVE-2018-54496.5A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does CVE-2018-54519.8In Philips Alice 6 System version R8.0.2 or prior, when an actor claims to have a given identity, the software does not prove or insufficienCVE-2018-54527.5A Stack-based Buffer Overflow issue was discovered in Emerson Process Management ControlWave Micro Process Automation Controller: ControlWavCVE-2018-54537.5An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and CVE-2018-54548.1Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could alloCVE-2018-54559.8A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 1606
CVE-2018-5441: High severity, CVSS 7.8 | Vulnix