CVE-2018-18551

MediumCVSS 6.1/10Last modified Jun 17, 2026

Description

ServersCheck Monitoring Software through 14.3.3 has Persistent and Reflected XSS via the sensors.html status parameter, sensors.html type parameter, sensors.html device parameter, report.html location parameter, group_delete.html group parameter, report_save.html query parameter, sensors.html location parameter, or group_delete.html group parameter.

Metrics

CVSS 3.0 6.1/10CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Oct 24, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-185526.5ServersCheck Monitoring Software through 14.3.3 allows local users to cause a denial of service (menu functionality loss) by creating an LNKCVE-2018-185536.1Leanote 2.6.1 has XSS via the Blog Basic Setting title field, which is mishandled during rendering of the "likes" page.CVE-2018-185559.9A sandbox escape issue was discovered in VyOS 1.1.8. It provides a restricted management shell for operator users to administer the device. CVE-2018-185569.9A privilege escalation issue was discovered in VyOS 1.1.8. The default configuration also allows operator users to execute the pppd binary wCVE-2018-185578.8LibTIFF 3.9.3, 3.9.4, 3.9.5, 3.9.6, 3.9.7, 4.0.0alpha4, 4.0.0alpha5, 4.0.0alpha6, 4.0.0beta7, 4.0.0, 4.0.1, 4.0.2, 4.0.3, 4.0.4, 4.0.4beta, CVE-2018-185586.4An issue was discovered in Espressif ESP-IDF 2.x and 3.x before 3.0.6 and 3.1.x before 3.1.1. Insufficient validation of input data in the 2CVE-2018-185598.1In the Linux kernel through 4.19, a use-after-free can occur due to a race condition between fanout_add from setsockopt and bind on an AF_PACVE-2018-185618.0An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base UnitCVE-2018-185628.8An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base UnitCVE-2018-185639.6An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (SerialCVE-2018-185647.4An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (SerialCVE-2018-185656.8An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (Serial
CVE-2018-18551: Medium severity, CVSS 6.1 | Vulnix