CVE-2018-15470

MediumCVSS 6.5/10Last modified Jun 17, 2026

Description

An issue was discovered in Xen through 4.11.x. The logic in oxenstored for handling writes depended on the order of evaluation of expressions making up a tuple. As indicated in section 7.7.3 "Operations on data structures" of the OCaml manual, the order of evaluation of subexpressions is not specified. In practice, different implementations behave differently. Thus, oxenstored may not enforce the configured quota-maxentity. This allows a malicious or buggy guest to write as many xenstore entries as it wishes, causing unbounded memory usage in oxenstored. This can lead to a system-wide DoS.

Metrics

CVSS 3.0 6.5/10CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 17, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-154717.8An issue was discovered in xenvif_set_hash_mapping in drivers/net/xen-netback/hash.c in the Linux kernel through 4.18.1, as used in Xen throCVE-2018-154727.5An issue was discovered in GitLab Community and Enterprise Edition before 11.1.7, 11.2.x before 11.2.4, and 11.3.x before 11.3.1. The diff fCVE-2018-154735.3OpenSSH through 7.7 is prone to a user enumeration vulnerability due to not delaying bailout for an invalid authenticating user until after CVE-2018-154749.6CSV Injection (aka Excel Macro Injection or Formula Injection) in /lib/plugins/usermanager/admin.php in DokuWiki 2018-04-22a and earlier allCVE-2018-154768.1An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58CVE-2018-154779.8myStrom WiFi Switch V1 devices before 2.66 did not sanitize a parameter received from the cloud that was used in an OS command. Malicious seCVE-2018-154788.1An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58CVE-2018-154796.5An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58CVE-2018-15484.3IBM API Connect 2018.1.0.0, 2018.2.1, 2018.2.2, 2018.2.3, and 2018.2.4 contains a vulnerability that could allow an authenticated user to obCVE-2018-154808.8An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58CVE-2018-154818.8Improper input sanitization within the restricted administration shell on UCOPIA Wireless Appliance devices using firmware version 5.1.x befCVE-2018-154829.8Certain LG devices based on Android 6.0 through 8.1 have incorrect access control for MLT application intents. The LG ID is LVE-SMP-180006.
CVE-2018-15470: Medium severity, CVSS 6.5 | Vulnix