CVE-2018-14776

MediumCVSS 5.4/10Last modified Jun 17, 2026

Description

Click Studios Passwordstate before 8.3 Build 8397 allows XSS by authenticated users via an uploaded HTML document.

Metrics

CVSS 3.0 5.4/10CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 1, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-147775.4An issue was discovered in DataLife Engine (DLE) through 13.0. An attacker can use XSS (related to the /addnews.html and /index.php?do=addneCVE-2018-147796.8A buffer overflow issue was discovered in the Yubico-Piv 1.5.0 smartcard driver. The file lib/ykpiv.c contains the following code in the funCVE-2018-14786.1IBM BigFix Platform 9.2.0 through 9.2.14 and 9.5 through 9.5.9 could allow a remote attacker to hijack the clicking action of the victim. ByCVE-2018-147804.6An out-of-bounds read issue was discovered in the Yubico-Piv 1.5.0 smartcard driver. The file lib/ykpiv.c contains the following code in theCVE-2018-147815.3Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled (non-defCVE-2018-147827.5NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The device allows access to configuration filCVE-2018-147838.8NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. A cross-site request forgery condition can ocCVE-2018-147846.1NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The device is vulnerable to several cross-sitCVE-2018-147857.5NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The directory of the device is listed openly CVE-2018-147869.4Becton, Dickinson and Company (BD) Alaris Plus medical syringe pumps (models Alaris GS, Alaris GH, Alaris CC, and Alaris TIVA) versions 2.3.CVE-2018-147877.8In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalCVE-2018-147885.3Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain
CVE-2018-14776: Medium severity, CVSS 5.4 | Vulnix