CVE-2018-1212

HighCVSS 8.8/10Last modified Jun 17, 2026

Description

The web-based diagnostics console in Dell EMC iDRAC6 (Monolithic versions prior to 2.91 and Modular all versions) contains a command injection vulnerability. A remote authenticated malicious iDRAC user with access to the diagnostics console could potentially exploit this vulnerability to execute arbitrary commands as root on the affected iDRAC system.

Metrics

CVSS 3.0 8.8/10CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jul 2, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-121208.1Node.js: All versions prior to Node.js 6.15.0: Debugger port 5858 listens on any interface by default: When the debugger is enabled with `noCVE-2018-121217.5Node.js: All versions prior to Node.js 6.15.0, 8.14.0, 10.14.0 and 11.3.0: Denial of Service with large HTTP headers: By using a combinationCVE-2018-121227.5Node.js: All versions prior to Node.js 6.15.0, 8.14.0, 10.14.0 and 11.3.0: Slowloris HTTP Denial of Service: An attacker can cause a Denial CVE-2018-121234.3Node.js: All versions prior to Node.js 6.15.0, 8.14.0, 10.14.0 and 11.3.0: Hostname spoofing in URL parser for javascript protocol: If a NodCVE-2018-121265.6Microarchitectural Store Buffer Data Sampling (MSBDS): Store buffers on some microprocessors utilizing speculative execution may allow an auCVE-2018-121275.6Microarchitectural Load Port Data Sampling (MLPDS): Load ports on some microprocessors utilizing speculative execution may allow an authentiCVE-2018-12138.8Dell EMC Isilon OneFS versions between 8.1.0.0 - 8.1.0.1, 8.0.1.0 - 8.0.1.2, and 8.0.0.0 - 8.0.0.6, versions 7.2.1.x, and version 7.1.1.11 aCVE-2018-121305.9Microarchitectural Fill Buffer Data Sampling (MFBDS): Fill buffers on some microprocessors utilizing speculative execution may allow an authCVE-2018-121317.8Permissions in the driver pack installers for Intel NVMe before version 4.0.0.1007 and Intel RSTe before version 4.7.0.2083 may allow an autCVE-2018-12147.0Dell EMC SupportAssist Enterprise version 1.1 creates a local Windows user account named "OMEAdapterUser" with a default password as part ofCVE-2018-121476.7Insufficient input validation in HECI subsystem in Intel(R) CSME before version 11.21.55, Intel® Server Platform Services before version 4.0CVE-2018-121487.8Privilege escalation in file permissions in Intel Driver and Support Assistant before 3.5.0.1 may allow an authenticated user to potentially
CVE-2018-1212: High severity, CVSS 8.8 | Vulnix