CVE-2017-9857

HighCVSS 8.1/10Last modified Jun 17, 2026

Description

An issue was discovered in SMA Solar Technology products. The SMAdata2+ communication protocol does not properly use authentication with encryption: it is vulnerable to man in the middle, packet injection, and replay attacks. Any setting change, authentication packet, scouting packet, etc. can be replayed, injected, or used for a man in the middle session. All functionalities available in Sunny Explorer can effectively be done from anywhere within the network as long as an attacker gets the packet setup correctly. This includes the authentication process for all (including hidden) access levels and the changing of settings in accordance with the gained access rights. Furthermore, because the SMAdata2+ communication channel is unencrypted, an attacker capable of understanding the protocol can eavesdrop on communications. NOTE: the vendor's position is that authentication with encryption is not required on an isolated subnetwork. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

Metrics

CVSS 3.0 8.1/10CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 5, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-98587.5An issue was discovered in SMA Solar Technology products. By sending crafted packets to an inverter and observing the response, active and iCVE-2017-98599.8An issue was discovered in SMA Solar Technology products. The inverters make use of a weak hashing algorithm to encrypt the password for REGCVE-2017-98609.8An issue was discovered in SMA Solar Technology products. An attacker can use Sunny Explorer or the SMAdata2+ network protocol to update theCVE-2017-98619.8An issue was discovered in SMA Solar Technology products. The SIP implementation does not properly use authentication with encryption: it isCVE-2017-98627.5An issue was discovered in SMA Solar Technology products. When signed into Sunny Explorer with a wrong password, it is possible to create a CVE-2017-98638.8An issue was discovered in SMA Solar Technology products. If a user simultaneously has Sunny Explorer running and visits a malicious host, cCVE-2017-98647.5An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. ThisCVE-2017-98655.5The function GfxImageColorMap::getGray in GfxState.cc in Poppler 0.54.0 allows remote attackers to cause a denial of service (stack-based buCVE-2017-98685.5In Mosquitto through 1.4.12, mosquitto.db (aka the persistence file) is world readable, which allows local users to obtain sensitive MQTT toCVE-2017-98695.5The II_step_one function in layer2.c in mpglib, as used in libmpgdecoder.a in LAME 3.99.5 and other products, allows remote attackers to cauCVE-2017-98705.5The III_i_stereo function in layer3.c in mpglib, as used in libmpgdecoder.a in LAME 3.99.5 and other products, allows remote attackers to caCVE-2017-98717.8The III_i_stereo function in layer3.c in mpglib, as used in libmpgdecoder.a in LAME 3.99.5 and other products, allows remote attackers to ca
CVE-2017-9857: High severity, CVSS 8.1 | Vulnix