CVE-2017-9656

CriticalCVSS 9.1/10Last modified Jun 17, 2026

Description

The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H.

Metrics

CVSS 3.0 9.1/10CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 24, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-96576.5Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the centraCVE-2017-96586.5Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not requCVE-2017-96598.8A Stack-Based Buffer Overflow issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. The stack-based buffCVE-2017-96608.8A Heap-Based Buffer Overflow was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. A heap-based buffer overfloCVE-2017-96617.0An Uncontrolled Search Path Element issue was discovered in SIMPlight SCADA Software version 4.3.0.27 and prior. The uncontrolled search patCVE-2017-96625.3An Improper Privilege Management issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. Monitouch V-SFT iCVE-2017-96637.5An Cleartext Storage of Sensitive Information issue was discovered in General Motors (GM) and Shanghai OnStar (SOS) SOS iOS Client 7.1. SuccCVE-2017-96649.8In ABB SREA-01 revisions A, B, C: application versions up to 3.31.5, and SREA-50 revision A: application versions up to 3.32.8, an attacker CVE-2017-96686.1In admin\addgroup.php in CMS Made Simple 2.1.6, when adding a user group, there is no XSS filtering, resulting in storage-type XSS generatioCVE-2017-96697.8A heap overflow in apk (Alpine Linux's package manager) allows a remote attacker to cause a denial of service, or achieve code execution by CVE-2017-96707.8An uninitialized stack variable vulnerability in load_tic_series() in set.c in gnuplot 5.2.rc1 allows an attacker to cause Denial of ServiceCVE-2017-96717.8A heap overflow in apk (Alpine Linux's package manager) allows a remote attacker to cause a denial of service, or achieve code execution, by
CVE-2017-9656: Critical severity, CVSS 9.1 | Vulnix