CVE-2017-6862

CriticalCVSS 9.8/10Known exploited (CISA KEV)Last modified Jun 17, 2026

Description

NETGEAR WNR2000v3 devices before 1.1.2.14, WNR2000v4 devices before 1.0.0.66, and WNR2000v5 devices before 1.0.0.42 allow authentication bypass and remote code execution via a buffer overflow that uses a parameter in the administration webapp. The NETGEAR ID is PSV-2016-0261.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
May 26, 2017
Last modified
Jun 17, 2026
Added to CISA KEV
Jun 8, 2022
NVD status
Analyzed

Related CVEs from 2017

CVE-2017-68645.4The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow an authenticated user to perform stored CrCVE-2017-68656.5A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SICVE-2017-68666.5A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated lowCVE-2017-68674.9A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 beCVE-2017-68688.1An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attaCVE-2017-68699.8A vulnerability was discovered in Siemens ViewPort for Web Office Portal before revision number 1453 that could allow an unauthenticated remCVE-2017-68707.4A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol imCVE-2017-68715.4A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClientCVE-2017-68726.5A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 2CVE-2017-68737.4A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulatCVE-2017-68747.0Race condition in kernel/ucount.c in the Linux kernel through 4.10.2 allows local users to cause a denial of service (use-after-free and sysCVE-2017-68776.1Cross-site scripting (XSS) vulnerability in SVG file handling in Lutim 0.7.1 and earlier allows remote attackers to inject arbitrary web scr
CVE-2017-6862: Critical severity, CVSS 9.8 | Vulnix