CVE-2017-6027

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution.

Metrics

CVSS 3.0 9.8/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
May 19, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-60289.8An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and ModCVE-2017-60295.4A Cross-Site Scripting issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. This may allow remote code execution.CVE-2017-60306.5A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions priorCVE-2017-60318.8A Header Injection issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. An "improper neutralization of HTTP headers foCVE-2017-60325.3A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has CVE-2017-60337.8A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versiCVE-2017-60349.8An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is tranCVE-2017-60358.8A Stack-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buCVE-2017-60366.5A Server-Side Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The weCVE-2017-60378.8A Heap-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a bufCVE-2017-60387.1A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The webCVE-2017-60395.3A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87. Use of a hard-coded
CVE-2017-6027: Critical severity, CVSS 9.8 | Vulnix