CVE-2017-6014

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

In Wireshark 2.2.4 and earlier, a crafted or malformed STANAG 4607 capture file will cause an infinite loop and memory exhaustion. If the packet size field in a packet header is null, the offset to read from will not advance, causing continuous attempts to read the same zero length packet. This will quickly exhaust all system memory.

Metrics

CVSS 3.0 7.5/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 17, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-60157.8Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, wCVE-2017-60167.3An Improper Access Control issue was discovered in LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA. The followingCVE-2017-60177.5A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR020CVE-2017-60186.1An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceSCVE-2017-60197.5An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid CVE-2017-60205.3Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA software versions prior to version 4.1.0.3237 do not neutralize eCVE-2017-60217.5In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, CVE-2017-60229.8A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA JourCVE-2017-60239.8An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following FaCVE-2017-60245.9A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix CVE-2017-60259.8A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web SCVE-2017-60269.1A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Versi
CVE-2017-6014: High severity, CVSS 7.5 | Vulnix