CVE-2017-5165

HighCVSS 7.6/10Last modified Jun 17, 2026

Description

An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. There is no CSRF Token generated per page and/or per (sensitive) function. Successful exploitation of this vulnerability can allow silent execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.

Metrics

CVSS 3.0 7.6/10CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 13, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-51669.8An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain pCVE-2017-51678.6An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own pCVE-2017-51687.5An issue was discovered in Hanwha Techwin Smart Security Manager Versions 1.5 and prior. Multiple Path Traversal vulnerabilities have been iCVE-2017-51697.5An issue was discovered in Hanwha Techwin Smart Security Manager Versions 1.5 and prior. Multiple Cross Site Request Forgery vulnerabilitiesCVE-2017-51707.2An Uncontrolled Search Path Element issue was discovered in Moxa SoftNVR-IA Live Viewer, Version 3.30.3122 and prior versions. An uncontrollCVE-2017-51739.8An Improper Neutralization of Special Elements (in an OS command) issue was discovered in Geutebruck IP Camera G-Cam/EFD-2250 Version 1.11.0CVE-2017-51749.8An Authentication Bypass issue was discovered in Geutebruck IP Camera G-Cam/EFD-2250 Version 1.11.0.12. An authentication bypass vulnerabiliCVE-2017-51757.8Advantech WebAccess 8.1 and earlier contains a DLL hijacking vulnerability which may allow an attacker to run a malicious DLL file within thCVE-2017-51767.0A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: ConnecteCVE-2017-51777.5A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior. A stack-based buffer overflow vulnerability hasCVE-2017-51789.8An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and pCVE-2017-51795.4Cross-site scripting (XSS) vulnerability in Tenable Nessus before 6.9.3 allows remote authenticated users to inject arbitrary web script or
CVE-2017-5165: High severity, CVSS 7.6 | Vulnix