CVE-2017-2673

HighCVSS 7.2/10Last modified Jun 17, 2026

Description

An authorization-check flaw was discovered in federation configurations of the OpenStack Identity service (keystone). An authenticated federated user could request permissions to a project and unintentionally be granted all related roles including administrative roles.

Metrics

CVSS 3.0 7.2/10CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jul 19, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-26745.4JBoss BRMS 6 and BPM Suite 6 before 6.4.3 are vulnerable to a stored XSS via several lists in Business Central. The flaw is due to lack of sCVE-2017-26757.8Little Snitch version 3.0 through 3.7.3 suffer from a local privilege escalation vulnerability in the installer part. The vulnerability is rCVE-2017-26806.5Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment CVE-2017-26816.5Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service conCVE-2017-26828.8The Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could allow a remote attacker to perform a Cross-Site RequestCVE-2017-26838.2A non-privileged user of the Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could perform a persistent Cross-SitCVE-2017-26849.0Siemens SIMATIC Logon prior to V1.5 SP3 Update 2 could allow an attacker with knowledge of a valid user name, and physical or network accessCVE-2017-26857.4Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and CVE-2017-26866.5Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the weCVE-2017-26876.1Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected CrCVE-2017-26888.8The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow remote attackers to perform actions with tCVE-2017-26898.8Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to o
CVE-2017-2673: High severity, CVSS 7.2 | Vulnix