CVE-2017-2304

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

Juniper Networks QFX3500, QFX3600, QFX5100, QFX5200, EX4300 and EX4600 devices running Junos OS 14.1X53 prior to 14.1X53-D40, 15.1X53 prior to 15.1X53-D40, 15.1 prior to 15.1R2, do not pad Ethernet packets with zeros, and thus some packets can contain fragments of system memory or data from previous packets. This issue is also known as 'Etherleak'

Metrics

CVSS 3.0 7.5/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
May 30, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-23058.8On Juniper Networks Junos Space versions prior to 16.1R1, due to an insufficient authorization check, readonly users on the Junos Space admiCVE-2017-23068.8On Juniper Networks Junos Space versions prior to 16.1R1, due to an insufficient authorization check, readonly users on the Junos Space admiCVE-2017-23076.1A reflected cross site scripting vulnerability in the administrative interface of Juniper Networks Junos Space versions prior to 16.1R1 may CVE-2017-23086.5An XML External Entity Injection vulnerability in Juniper Networks Junos Space versions prior to 16.1R1 may allow an authenticated user to rCVE-2017-23095.9On Juniper Networks Junos Space versions prior to 16.1R1 when certificate based authentication is enabled for the Junos Space cluster, some CVE-2017-23105.3A firewall bypass vulnerability in the host based firewall of Juniper Networks Junos Space versions prior to 16.1R1 may permit certain craftCVE-2017-23115.3On Juniper Networks Junos Space versions prior to 16.1R1, an unauthenticated remote attacker with network access to Junos space device can eCVE-2017-23126.5On Juniper Networks devices running Junos OS affected versions and with LDP enabled, a specific LDP packet destined to the RE (Routing EnginCVE-2017-23137.5Juniper Networks devices running affected Junos OS versions may be impacted by the receipt of a crafted BGP UPDATE which can lead to an rpd CVE-2017-23147.5Receipt of a malformed BGP OPEN message may cause the routing protocol daemon (rpd) process to crash and restart. By continuously sending spCVE-2017-23157.5On Juniper Networks EX Series Ethernet Switches running affected Junos OS versions, a vulnerability in IPv6 processing has been discovered tCVE-2017-23166.5A buffer overflow vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an auth
CVE-2017-2304: High severity, CVSS 7.5 | Vulnix