CVE-2017-14102

HighCVSS 7.8/10Last modified Jun 17, 2026

Description

MIMEDefang 2.80 and earlier creates a PID file after dropping privileges to a non-root account, which might allow local users to kill arbitrary processes by leveraging access to this non-root account for PID file modification before a root script executes a "kill `cat /pathname`" command, as demonstrated by the init-script.in and mimedefang-init.in scripts.

Metrics

CVSS 3.0 7.8/10CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Sep 1, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-141038.8The ReadJNGImage and ReadOneJNGImage functions in coders/png.c in GraphicsMagick 1.3.26 do not properly manage image pointers after certain CVE-2017-141057.8HiveManager Classic through 8.1r1 allows arbitrary JSP code execution by modifying a backup archive before a restore, because the restore feCVE-2017-141065.5The tcp_disconnect function in net/ipv4/tcp.c in the Linux kernel before 4.12 allows local users to cause a denial of service (__tcp_select_CVE-2017-141076.5The _zip_read_eocd64 function in zip_open.c in libzip before 1.3.0 mishandles EOCD records, which allows remote attackers to cause a denial CVE-2017-141085.5libgedit.a in GNOME gedit through 3.22.1 allows remote attackers to cause a denial of service (CPU consumption) via a file that begins with CVE-2017-14117.5IBM Security Identity Governance Virtual Appliance 5.2 through 5.2.3.2 does not require that users should have strong passwords by default, CVE-2017-141117.2The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domaCVE-2017-141146.5RTPproxy through 2.2.alpha.20160822 has a NAT feature that results in not properly determining the IP address and port number of the legitimCVE-2017-141158.1The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG589 and NVG599 devices, when IP Passthrough mode is not used, configures ssh-permanentCVE-2017-141168.1The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG599 device, when IP Passthrough mode is not used, configures WAN access to a caserver CVE-2017-141175.9The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG589 and NVG599 devices, when IP Passthrough mode is not used, configures an unauthentiCVE-2017-141188.8In the EyesOfNetwork web interface (aka eonweb) 5.1-0, module\tool_all\tools\interface.php does not properly restrict exec calls, which allo
CVE-2017-14102: High severity, CVSS 7.8 | Vulnix