CVE-2017-12708

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

An Improper Restriction Of Operations Within The Bounds Of A Memory Buffer issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Researchers have identified multiple vulnerabilities that allow invalid locations to be referenced for the memory buffer, which may allow an attacker to execute arbitrary code or cause the system to crash.

Metrics

CVSS 3.0 9.8/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 30, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-127095.3A Use of Hard-Coded Credentials issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions oldeCVE-2017-12717.5IBM Security Guardium 9.0, 9.1, and 9.5 supports interaction between multiple actors and allows those actors to negotiate which algorithm shCVE-2017-127107.5A SQL Injection issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. By submitting a specially crafted parameter, itCVE-2017-127117.8An Incorrect Privilege Assignment issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A built-in user account has bCVE-2017-127128.8The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and CVE-2017-127137.8An Incorrect Permission Assignment for Critical Resource issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. MultipCVE-2017-127146.5Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" coCVE-2017-127166.5Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communicCVE-2017-127177.8An Uncontrolled Search Path Element issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A maliciously crafted dll fCVE-2017-127188.1A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. ACVE-2017-127197.5An Untrusted Pointer Dereference issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A remote attacker is able to eCVE-2017-12725.3IBM Security Guardium 10.0 and 10.5 stores sensitive information in URL parameters. This may lead to information disclosure if unauthorized
CVE-2017-12708: Critical severity, CVSS 9.8 | Vulnix