CVE-2014-2364

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

Multiple stack-based buffer overflows in Advantech WebAccess before 7.2 allow remote attackers to execute arbitrary code via a long string in the (1) ProjectName, (2) SetParameter, (3) NodeName, (4) CCDParameter, (5) SetColor, (6) AlarmImage, (7) GetParameter, (8) GetColor, (9) ServerResponse, (10) SetBaud, or (11) IPAddress parameter to an ActiveX control in (a) webvact.ocx, (b) dvs.ocx, or (c) webdact.ocx.

Metrics

CVSS 2.0 7.5/10AV:N/AC:L/Au:N/C:P/I:P/A:P

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jul 19, 2014
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2014

CVE-2014-23655.5Unspecified vulnerability in Advantech WebAccess before 7.2 allows remote authenticated users to create or delete arbitrary files via unknowCVE-2014-23664.0upAdminPg.asp in Advantech WebAccess before 7.2 allows remote authenticated users to discover credentials by reading HTML source code.CVE-2014-23674.3The ChkCookie subroutine in an ActiveX control in broadweb/include/gChkCook.asp in Advantech WebAccess before 7.2 allows remote attackers toCVE-2014-23685.0The BrowseFolder method in the bwocxrun ActiveX control in Advantech WebAccess before 7.2 allows remote attackers to read arbitrary files viCVE-2014-23696.0Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8CVE-2014-23703.5Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x alCVE-2014-23737.5The AXN-NET Ethernet module accessory 3.04 for the Accuenergy Acuvim II allows remote attackers to discover passwords and modify settings viCVE-2014-23747.5The AXN-NET Ethernet module accessory 3.04 for the Accuenergy Acuvim II allows remote attackers to discover passwords and modify settings viCVE-2014-23759.0Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to read or write to arbitrarCVE-2014-23767.5SQL injection vulnerability in Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackeCVE-2014-23775.0Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to discover full pathnames vCVE-2014-23787.6Sensys Networks VSN240-F and VSN240-T sensors VDS before 2.10.1 and TrafficDOT before 2.10.3 do not verify the integrity of downloaded updat
CVE-2014-2364: High severity, CVSS 7.5 | Vulnix