CVE-2013-2806

HighCVSS 7.5/10Last modified Jun 16, 2026

Description

Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size.” Then the service will calculate an incorrect value for the “End of Current Record” field causing access violations that lead to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation security advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599

Metrics

CVSS 3.0 7.5/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 26, 2019
Last modified
Jun 16, 2026
NVD status
Modified

Related CVEs from 2013

CVE-2013-28077.5Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPRCVE-2013-28089.3Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management VasculaCVE-2013-28097.1The DNP Master Driver in the OSIsoft PI Interface before 3.1.2.54 for DNP3 allows remote attackers to cause a denial of service (interface sCVE-2013-281010.0Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with softwaCVE-2013-28117.1The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrCVE-2013-28137.1The DNP3 component in Cooper Power Systems SMP 4, 4/DP, and 16 gateways allows remote attackers to cause a denial of service (reboot or linkCVE-2013-28147.1Cooper Power Systems Cybectec DNP3 Master OPC Server allows remote attackers to cause a denial of service (unhandled exception and process cCVE-2013-28164.7The DNP3 component in Cooper Power Systems SMP 4, 4/DP, and 16 gateways allows physically proximate attackers to cause a denial of service (CVE-2013-28179.3An ActiveX control in IcoLaunch.dll in Mitsubishi Electric Automation MC-WorX Suite 8.02 allows user-assisted remote attackers to execute arCVE-2013-28184.7The DNP Master Driver in Alstom e-terracontrol 3.5, 3.6, and 3.7 allows physically proximate attackers to cause a denial of service (infinitCVE-2013-28199.3The Sierra Wireless AirLink Raven X EV-DO gateway 4221_4.0.11.003 and 4228_4.0.11.003 allows remote attackers to install Trojan horse firmwaCVE-2013-282010.0The Sierra Wireless AirLink Raven X EV-DO gateway 4221_4.0.11.003 and 4228_4.0.11.003 allows remote attackers to reprogram the firmware via
CVE-2013-2806: High severity, CVSS 7.5 | Vulnix