CVE-2012-4687

HighCVSS 7.6/10Last modified Jun 16, 2026

Description

Post Oak AWAM Bluetooth Reader Traffic System does not use a sufficient source of entropy for private keys, which makes it easier for man-in-the-middle attackers to spoof a device by predicting a key value.

Metrics

CVSS 2.0 7.6/10AV:N/AC:H/Au:N/C:C/I:C/A:C

Weakness enumeration

Affected software

VendorProductVersions
Post Oak Traffic SystemsAWAM Bluetooth Reader Traffic SystemAll versions

References

Timeline

Published
Dec 8, 2012
Last modified
Jun 16, 2026
NVD status
Modified

Related CVEs from 2012

CVE-2012-46887.5The Central application in i-GEN opLYNX before 2.01.9 allows remote attackers to bypass authentication via vectors involving the disabling oCVE-2012-46894.3Integer overflow in CimWebServer.exe in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY 4.01 through 8.0, and Proficy Process SystemCVE-2012-46907.1Rockwell Automation Allen-Bradley MicroLogix controller 1100, 1200, 1400, and 1500; SLC 500 controller platform; and PLC-5 controller platfoCVE-2012-46913.3Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory CVE-2012-46931.9Invensys Wonderware InTouch 2012 R2 and earlier and Siemens ProcessSuite use a weak encryption algorithm for data in Ps_security.ini, which CVE-2012-46947.6Moxa EDR-G903 series routers with firmware before 2.11 do not use a sufficient source of entropy for (1) SSH and (2) SSL keys, which makes iCVE-2012-46957.1LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 alCVE-2012-46966.9Buffer overflow in Beijer ADP 6.5.0-180_R1967 and 6.5.1-186_R2942, and H-Designer 6.5.0 B180_R1967, allows local users to gain privileges byCVE-2012-469710.0TURCK BL20 Programmable Gateway and BL67 Programmable Gateway have hardcoded accounts, which allows remote attackers to obtain administrativCVE-2012-46984.3Siemens RuggedCom Rugged Operating System (ROS) before 3.12, ROX I OS through 1.14.5, ROX II OS through 2.3.0, and RuggedMax OS through 4.2.CVE-2012-47009.3Multiple buffer overflows in an ActiveX control in PE3DO32A.ocx in IntegraXor SCADA Server 4.00 build 4250.0 and earlier allow remote attackCVE-2012-47019.3Directory traversal vulnerability in Tridium Niagara AX 3.5, 3.6, and 3.7 allows remote attackers to read sensitive files, and consequently
CVE-2012-4687: High severity, CVSS 7.6 | Vulnix