CVE-2012-0229

CriticalCVSS 10.0/10Last modified Jun 16, 2026

Description

The Data Archiver service in GE Intelligent Platforms Proficy Historian 4.5 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted session on TCP port 14000 to (1) ihDataArchiver.exe or (2) ihDataArchiver_x64.exe.

Metrics

CVSS 2.0 10.0/10AV:N/AC:L/Au:N/C:C/I:C/A:C

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 15, 2012
Last modified
Jun 16, 2026
NVD status
Modified

Related CVEs from 2012

CVE-2012-023010.0PRRDS.exe in the Proficy Remote Data Service in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers CVE-2012-023110.0PRLicenseMgr.exe in the Proficy Server License Manager in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote CVE-2012-02326.4Directory traversal vulnerability in rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information PCVE-2012-02334.3Cross-site scripting (XSS) vulnerability in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to inject arbitrary web script oCVE-2012-02347.5SQL injection vulnerability in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to execute arbitrary SQL commands via a malfoCVE-2012-02356.0Cross-site request forgery (CSRF) vulnerability in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to hijack the authenticatCVE-2012-02365.0Advantech/BroadWin WebAccess 7.0 and earlier allows remote attackers to obtain sensitive information via a direct request to a URL. NOTE: tCVE-2012-02376.4Advantech/BroadWin WebAccess before 7.0 allows remote attackers to (1) enable date and time syncing or (2) disable date and time syncing viaCVE-2012-023810.0Stack-based buffer overflow in opcImg.asp in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to execute arbitrary code via uCVE-2012-02395.0uaddUpAdmin.asp in Advantech/BroadWin WebAccess before 7.0 does not properly perform authentication, which allows remote attackers to modifyCVE-2012-024010.0GbScriptAddUp.asp in Advantech/BroadWin WebAccess before 7.0 does not properly perform authentication, which allows remote attackers to execCVE-2012-02415.0Advantech/BroadWin WebAccess before 7.0 allows remote attackers to cause a denial of service (memory corruption) via a modified stream ident
CVE-2012-0229: Critical severity, CVSS 10.0 | Vulnix