CVE-2011-4506

HighCVSS 7.5/10Last modified Jun 16, 2026

Description

The UPnP IGD implementation on the Thomson (aka Technicolor) TG585 with firmware 7.x before 7.4.3.2 allows remote attackers to establish arbitrary port mappings by sending a UPnP AddPortMapping action in a SOAP request to the WAN interface, related to an "external forwarding" vulnerability.

Metrics

CVSS 2.0 7.5/10AV:N/AC:L/Au:N/C:P/I:P/A:P

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Nov 22, 2011
Last modified
Jun 16, 2026
NVD status
Modified

Related CVEs from 2011

CVE-2011-45077.5The D-Link DIR-685 router, when certain WPA and WPA2 configurations are used, does not maintain an encrypted wireless network during transfeCVE-2011-45089.3The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, CVE-2011-450910.0The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and MobCVE-2011-45104.3Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aCVE-2011-45114.3Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aCVE-2011-45125.0CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portaCVE-2011-451310.0Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMICVE-2011-451410.0The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and MobiCVE-2011-45154.6Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable filCVE-2011-45166.8Heap-based buffer overflow in the jpc_cox_getcompparms function in libjasper/jpc/jpc_cs.c in JasPer 1.900.1 allows remote attackers to execuCVE-2011-45176.8The jpc_crg_getparms function in libjasper/jpc/jpc_cs.c in JasPer 1.900.1 uses an incorrect data type during a certain size calculation, whiCVE-2011-45185.0Directory traversal vulnerability in the PmWebDir object in the web server in MICROSYS PROMOTIC before 8.1.5 allows remote attackers to read
CVE-2011-4506: High severity, CVSS 7.5 | Vulnix