CVE-2010-5298

MediumCVSS 4.0/10Last modified Jun 16, 2026

Description

Race condition in the ssl3_read_bytes function in s3_pkt.c in OpenSSL through 1.0.1g, when SSL_MODE_RELEASE_BUFFERS is enabled, allows remote attackers to inject data across sessions or cause a denial of service (use-after-free and parsing error) via an SSL connection in a multithreaded environment.

Metrics

CVSS 2.0 4.0/10AV:N/AC:H/Au:N/C:N/I:P/A:P

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 14, 2014
Last modified
Jun 16, 2026
NVD status
Modified

Related CVEs from 2010

CVE-2010-52996.8Stack-based buffer overflow in MicroP 0.1.1.1600 allows remote attackers to execute arbitrary code via a crafted .mppl file. NOTE: it has bCVE-2010-53006.8Stack-based buffer overflow in Jzip 1.3 through 2.0.0.132900 allows remote attackers to cause a denial of service (crash) and possibly execuCVE-2010-53017.5Stack-based buffer overflow in Kolibri 2.0 allows remote attackers to execute arbitrary code via a long URI in a HEAD request.CVE-2010-53024.3Cross-site scripting (XSS) vulnerability in timthumb.php in TimThumb before 1.15 as of 20100908 (r88), as used in multiple products, allows CVE-2010-53034.3Cross-site scripting (XSS) vulnerability in the displayError function in timthumb.php in TimThumb before 1.15 (r85), as used in multiple proCVE-2010-53047.5A NULL pointer dereference flaw was found in the way LibVNCServer before 0.9.9 handled certain ClientCutText message. A remote attacker coulCVE-2010-53059.8The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx anCVE-2010-530610.0GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and atCVE-2010-530710.0The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of (1) operator for the root account, (2) adw2.0 for the admiCVE-2010-530810.0GE Healthcare Optima MR360 does not require authentication for the HIPAA emergency login procedure, which allows physically proximate users CVE-2010-530910.0GE Healthcare CADStream Server has a default password of confirma for the admin user, which has unspecified impact and attack vectors.CVE-2010-531010.0The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact an
CVE-2010-5298: Medium severity, CVSS 4.0 | Vulnix