CVE-2026-80238

CriticalCVSS 9.3/10Last modified Sep 11, 2026

Description

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Execution with Unnecessary Privileges vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to Protection mechanism bypass. This vulnerability is considered critical because a low-privileged operator with SSH access to the SCG host can gain root-level access to the host without requiring a password by leveraging the exposed Docker socket. Additionally, an attacker who compromises a service running within the orchestrator container can access the same socket and escape the container boundary to obtain host-level control. Dell recommends that customers upgrade at the earliest opportunity.

Metrics

CVSS 3.1 9.3/10CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Sep 7, 2026
Last modified
Sep 11, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-802392.4Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Exposure of SensiCVE-2026-80249.8A remote, unauthenticated attacker may exploit a deserialization of untrusted data vulnerability in ibaPDA or ibaDatCoordinator to gain fullCVE-2026-80259.8Improper neutralization of special elements used in an SQL command ('SQL injection') vulnerability in MOSK Information Technologies Ltd. CBSCVE-2026-802537.0An improper physical access control issue exists in ShizenBox2 (dev-conf). If exploited, an attacker with physical access to the product mayCVE-2026-802547.1Authorization bypass through user-controlled key issue exists in ShizenBox2 (edge-app). If exploited, an attacker who can log in to the prodCVE-2026-802557.5A `Set-Cookie:` header using tab (horizontal tab, ASCII code 9) instead of space (ascii code 32) immediately before the `Secure` attribute cCVE-2026-80265.3A security flaw has been discovered in FlowiseAI Flowise up to 3.0.12. Affected is the function Login of the file packages/server/src/enterpCVE-2026-80274.3A weakness has been identified in FlowiseAI Flowise up to 3.0.12. Affected by this vulnerability is an unknown functionality of the componenCVE-2026-802747.5If a BIND resolver sends a query for a DNSSEC-signed authoritative zone, and the authoritative server replies with a valid wildcard answer aCVE-2026-802758.8Comelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 fail to enforce server-side authorization on an aCVE-2026-802767.5Comelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 expose a network-accessible management interface CVE-2026-80283.7A vulnerability was detected in FlowiseAI Flowise up to 3.0.12. This affects the function verify of the file packages/server/src/enterprise/