CVE-2026-55707

HighCVSS 7.1/10Last modified Oct 24, 2026

Description

In OpenStack Neutron before 28.0.2, the subnetpool onboarding API does not verify ownership of the target subnets. An authenticated user can onboard subnets from another project's shared network into their own subnetpool, mutating the victim's subnet state and altering L3 routing and address scope behavior for victim routers.

Metrics

CVSS 4.0 7.1/10CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 5, 2026
Last modified
Oct 24, 2026
NVD status
Deferred

Related CVEs from 2026

CVE-2026-557083.1In NLnet Labs Unbound 1.6.0 up to and including 1.25.1, the 'view_local_data' and 'view_local_datas' commands of 'unbound-control' create a CVE-2026-55717.5A vulnerability was identified in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. The impacted element is an unknown function of the file /fs CVE-2026-557175.9In NLnet Labs Unbound 1.10.0 up to and including 1.25.1, when 'serve-expired: yes' is set together with a 'response-ip: <net> redirect' /'reCVE-2026-55724.3A security flaw has been discovered in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. This affects an unknown function. Performing a manipulaCVE-2026-557219.3Storage Concentrator (SC & SCVM) is vulnerable to SQL injection through cookie values processed by the login.pl and debug.pl scripts. The coCVE-2026-557238.3When NGINX Ingress Controller is configured with Custom Resource Definitions (CRDs) or Ingress annotations, an injection vulnerability existCVE-2026-557265.3The Azure Blob Storage container used for Gardyn device logs is publicly listable without authentication. A malicious user would be able to CVE-2026-557277.5A flaw in the authentication mechanism for video stream requests in Genetec Security Center 5.14.0.0 prior to build 5.14.178.18 may allow anCVE-2026-557283.8Stack-based Buffer Overflow (CWE-121) in `/usr/bin/ltsudo` `cmd_ipaddr_conflict` in Loytec LIP-ME201C, L-INX, L-GATE, L-ROC, L-IOB, L-DALI,CVE-2026-557297.7Exposure of Sensitive Information (CWE-200) in LWEB802 browser `localStorage` in Loytec LWEB-802 before 5.0.8 on all platforms allows an unaCVE-2026-55739.8A weakness has been identified in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. This impacts an unknown function of the file /fs. Executing CVE-2026-557308.7Reflected Cross-Site Scripting (CWE-79) in LWEB802 in Loytec LWEB-802 before 5.0.8 on all platforms allows an unauthenticated remote attacke
CVE-2026-55707: High severity, CVSS 7.1 | Vulnix