CVE-2026-39454

HighCVSS 8.5/10Last modified Oct 26, 2026

Description

SKYSEA Client View and SKYMEC IT Manager provided by Sky Co.,LTD. configure the installation folder with improper file access permission settings. A non-administrative user may manipulate and/or place arbitrary files within the installation folder of the product. As a result, arbitrary code may be executed with the administrative privilege.

Metrics

CVSS 4.0 8.5/10CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Weakness enumeration

Affected software

VendorProductVersions
Sky Co.,LTD.SKYSEA Client ViewVer.21.200.07j and earlier
Sky Co.,LTD.SKYMEC IT ManagerVer.2024.005.10a and earlier

References

Timeline

Published
Apr 20, 2026
Last modified
Oct 26, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-394557.5When the BIG-IP Configuration utility is configured to use Lightweight Directory Access Protocol (LDAP) authentication, undisclosed traffic CVE-2026-394565.6Improper input validation for some Media Transcode Accelerator before version 1.0.0-00128 within Ring 3: User Applications may allow a deniaCVE-2026-394577.8When exchanging data over a socket, libnv uses select(2) to wait for data to arrive. However, it does not verify whether the provided sockeCVE-2026-394587.5When a BIG-IP is configured with DNS caching (Such as a DNS profile with caching enabled, SSL Orchestrator, Advanced WAF DoS protection), uCVE-2026-394597.2A vulnerability exists in iControl REST and the TMOS Shell (tmsh) where a highly privileged, authenticated attacker with at least the ManageCVE-2026-39463.5A vulnerability was detected in PHPEMS 11.0. The affected element is an unknown function of the file /index.php?ask=app-ask. Performing a maCVE-2026-394608.1Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file. With administratoCVE-2026-394618.8libcasper(3) communicates with helper processes via UNIX domain sockets, and uses the select(2) system call to wait for data to become availCVE-2026-394628.1A vulnerability exists in SenseLive X3050’s web management interface in which password updates are not reliably applied due to improper handCVE-2026-394637.1Unauthenticated Cross Site Scripting (XSS) in ManageWP Worker <= 4.9.31 versions.CVE-2026-394645.5Server-Side Request Forgery (SSRF) vulnerability in SeedProd Coming Soon Page, Under Construction & Maintenance Mode by SeedProd coming-soonCVE-2026-394659.1Editor Remote Code Execution (RCE) in Responsive Slider by MetaSlider <= 3.106.0 versions.
CVE-2026-39454: High severity, CVSS 8.5 | Vulnix