CVE-2026-33780

MediumCVSS 6.5/10Last modified Jun 17, 2026

Description

A Missing Release of Memory after Effective Lifetime vulnerability in the Layer 2 Address Learning Daemon (l2ald) of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent, unauthenticated attacker to cause a memory leak ultimately leading to a Denial of Service (DoS).

In an EVPN-MPLS scenario, routes learned from remote multi-homed Provider Edge (PE) devices are programmed as ESI routes. Due to a logic issue in the l2ald memory management, memory allocated for these routes is not released when there is churn for these routes. As a result, memory leaks in the l2ald process which will ultimately lead to a crash and restart of l2ald.

Use the following command to monitor the memory consumption by l2ald:

user@device> show system process extensive | match "PID|l2ald"

This issue affects:

Junos OS:

* all versions before 22.4R3-S5, * 23.2 versions before 23.2R2-S3, * 23.4 versions before 23.4R2-S4, * 24.2 versions before 24.2R2;

Junos OS Evolved:

* all versions before 22.4R3-S5-EVO, * 23.2 versions before 23.2R2-S3-EVO, * 23.4 versions before 23.4R2-S4-EVO, * 24.2 versions before 24.2R2-EVO.

Metrics

CVSS 3.1 6.5/10CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 9, 2026
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-337816.5An Improper Check for Unusual or Exceptional Conditions vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on CVE-2026-337826.5A Missing Release of Memory after Effective Lifetime vulnerability in the DHCP daemon (jdhcpd) of Juniper Networks Junos OS on MX Series, alCVE-2026-337836.5A Function Call With Incorrect Argument Type vulnerability in the sensor interface of Juniper Networks Junos OS Evolved on PTX Series allowsCVE-2026-337849.8A Use of Default Password vulnerability in the Juniper Networks Support Insights (JSI) Virtual Lightweight Collector (vLWC) allows an unCVE-2026-337858.8A Missing Authorization vulnerability in the CLI of Juniper Networks Junos OS on MX Series allows a local, authenticated user with low priviCVE-2026-337865.5An Improper Check for Unusual or Exceptional Conditions vulnerability in the chassis control daemon (chassisd) of Juniper Networks Junos OS CVE-2026-337875.5An Improper Check for Unusual or Exceptional Conditions vulnerability in the chassis control daemon (chassisd) of Juniper Networks Junos OS CVE-2026-337887.8A Missing Authentication for Critical Function vulnerability in the Flexible PIC Concentrators (FPCs) of Juniper Networks Junos OS Evolved oCVE-2026-337899.8A Stack-based Buffer Overflow vulnerability in the routing protocol daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows anCVE-2026-33798.8A vulnerability has been found in Tenda F453 1.0.0.3. This vulnerability affects the function fromSetIpBind of the file /goform/SetIpBind. TCVE-2026-337907.5An Improper Check for Unusual or Exceptional Conditions vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series CVE-2026-337916.7An OS Command Injection vulnerability in the CLI processing of Juniper Networks Junos OS and Junos OS Evolved allows a local, high-privilege