Description
In the Linux kernel, the following vulnerability has been resolved:
net/x25: Fix overflow when accumulating packets
Add a check to ensure that `x25_sock.fraglen` does not overflow.
The `fraglen` also needs to be resetted when purging `fragment_queue` in `x25_clear_queues()`.
Metrics
CVSS 3.1 7.5/10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HWeakness enumeration
Affected software
| Vendor | Product | Versions |
|---|---|---|
| Linux | Linux | >= 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, < 96fc16370b0bceb289c7e0479bd0540b81e257aa; >= 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, < 798d613afb64b01a203f448fb0f43c37c6afe79d; >= 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, < 6e568835ea54a3e1d08e310e34f95d434e739477; >= 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, < 1734bd85c5e0a7a801295b729efb56b009cb8fc3; >= 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, < 4e2d1bcef78d21247fe8fef13bc7ed95885df2b5; >= 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, < 8c92969c197b91c134be27dc3afb64ab468853a9; >= 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, < f953f11ccf4afe6feb635c08145f4240d9a6b544; >= 1da177e4c3f41524e886b7f1b8a0c1fc7321cac2, < a1822cb524e89b4cd2cf0b82e484a2335496a6d9 |
| Linux | Linux | 2.6.12 |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.7, < * |
References
- https://git.kernel.org/stable/c/1734bd85c5e0a7a801295b729efb56b009cb8fc3Patch
- https://git.kernel.org/stable/c/4e2d1bcef78d21247fe8fef13bc7ed95885df2b5Patch
- https://git.kernel.org/stable/c/6e568835ea54a3e1d08e310e34f95d434e739477Patch
- https://git.kernel.org/stable/c/798d613afb64b01a203f448fb0f43c37c6afe79dPatch
- https://git.kernel.org/stable/c/8c92969c197b91c134be27dc3afb64ab468853a9Patch
- https://git.kernel.org/stable/c/96fc16370b0bceb289c7e0479bd0540b81e257aaPatch
- https://git.kernel.org/stable/c/a1822cb524e89b4cd2cf0b82e484a2335496a6d9Patch
- https://git.kernel.org/stable/c/f953f11ccf4afe6feb635c08145f4240d9a6b544Patch
- https://cert-portal.siemens.com/productcert/html/ssa-019113.html
- https://cert-portal.siemens.com/productcert/html/ssa-082556.html
- https://cert-portal.siemens.com/productcert/html/ssa-457936.html
Timeline
- Published
- Apr 13, 2026
- Last modified
- Oct 15, 2026
- NVD status
- Modified