CVE-2026-27837

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

Dottie provides nested object access and manipulation in JavaScript. Versions 2.0.4 through 2.0.6 contain an incomplete fix for CVE-2023-26132. The prototype pollution guard introduced in commit `7d3aee1` only validates the first segment of a dot-separated path, allowing an attacker to bypass the protection by placing `__proto__` at any position other than the first. Both `dottie.set()` and `dottie.transform()` are affected. Version 2.0.7 contains an updated fix to address the residual vulnerability.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 26, 2026
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-278383.5wger is a free, open-source workout and fitness manager. Five routine detail action endpoints check a cache before calling `self.get_object(CVE-2026-278394.3wger is a free, open-source workout and fitness manager. In versions up to and including 2.4, three `nutritional_values` action endpoints feCVE-2026-27849.8Mitigation bypass in the DOM: Security component. This vulnerability was fixed in Firefox 148, Firefox ESR 140.8, Thunderbird 148, and ThundCVE-2026-278404.3ZITADEL is an open source identity management platform. Starting in version 2.31.0 and prior to versions 3.4.7 and 4.11.0, opaque OIDC accesCVE-2026-278418.1A vulnerability in SenseLive X3050's web management interface allows state-changing operations to be triggered without proper Cross-Site ReqCVE-2026-278429.3Authentication bypass issue exists in MR-GM5L-S1 and MR-GM5A-L1, which may allow an attacker to bypass authentication and change the device CVE-2026-278439.1A vulnerability exists in SenseLive X3050's web management interface that allows critical configuration parameters to be modified without suCVE-2026-278442.7Uncaught Exception (CWE-248) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated and authorized operCVE-2026-278466.2Due to missing authentication, a user with physical access to the device can misuse the mesh functionality for adding a new mesh device to tCVE-2026-278479.8Due to improper neutralization of special elements, SQL statements can be injected via the handshake of a TLS-SRP connection. This can be usCVE-2026-278489.8Due to missing neutralization of special elements, OS commands can be injected via the handshake of a TLS-SRP connection, which are ultimateCVE-2026-278499.8Due to missing neutralization of special elements, OS commands can be injected via the update functionality of a TLS-SRP connection, which i
CVE-2026-27837: Critical severity, CVSS 9.8 | Vulnix