CVE-2026-26357

MediumCVSS 5.4/10Last modified Jun 17, 2026

Description

Dell Unisphere for PowerMax, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to the execution of malicious HTML or JavaScript code in a victim user's web browser in the context of the vulnerable web application. Exploitation may lead to information disclosure, session theft, or client-side request forgery.

Metrics

CVSS 3.1 5.4/10CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

Weakness enumeration

Affected software

VendorProductVersions
DellUnisphere for PowerMax 9.2.4.18>= N/A, < 9.2.4.19
DellUnisphere for PowerMax Virtual Appliance 9.2.4.17>= N/A, < 9.2.4.19

References

Timeline

Published
Feb 17, 2026
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2026

CVE-2026-263588.8Dell Unisphere for PowerMax, version(s) 10.2, contain(s) a Missing Authorization vulnerability. A low privileged attacker with remote accessCVE-2026-263598.8Dell Unisphere for PowerMax, version(s) 10.2, contain(s) an External Control of File Name or Path vulnerability. A low privileged attacker wCVE-2026-26365.5This vulnerability is caused by a CWE‑159: "Improper Handling of Invalid Use of Special Elements" weakness, which leads to an unrecoverable CVE-2026-263608.1Dell Unisphere for PowerMax, version(s) 10.2, contain(s) an External Control of File Name or Path vulnerability. A low privileged attacker wCVE-2026-263616.5Dell Unisphere for PowerMax, version(s) 10.2, contain(s) an External Control of File Name or Path vulnerability. A low privileged attacker wCVE-2026-263628.1Dell Unisphere for PowerMax, version(s) 10.2, contain(s) a Relative Path Traversal vulnerability. A low privileged attacker with remote acceCVE-2026-263654.0Akamai Ghost on Akamai CDN edge servers before 2026-02-06 mishandles processing of custom hop-by-hop HTTP headers, where an incoming requestCVE-2026-263669.8eNet SMART HOME server 2.2.1 and 2.3.1 ships with default credentials (user:user, admin:admin) that remain active after installation and comCVE-2026-263678.1eNet SMART HOME server 2.2.1 and 2.3.1 contains a missing authorization vulnerability in the deleteUserAccount JSON-RPC method that permits CVE-2026-263688.8eNet SMART HOME server 2.2.1 and 2.3.1 contains a missing authorization vulnerability in the resetUserPassword JSON-RPC method that allows aCVE-2026-263698.8eNet SMART HOME server 2.2.1 and 2.3.1 contains a privilege escalation vulnerability due to insufficient authorization checks in the setUserCVE-2026-26377.8iBoysoft NTFS for Mac contains a local privilege escalation vulnerability in its privileged helper daemon ntfshelperd. The daemon exposes an
CVE-2026-26357: Medium severity, CVSS 5.4 | Vulnix