CVE-2026-24429

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) ship with a predefined default password for a built-in authentication account that is not required to be changed during initial configuration. An attacker can leverage these default credentials to gain authenticated access to the management interface.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 26, 2026
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-24435.3A flaw was identified in libsoup, a widely used HTTP library in GNOME-based systems. When processing specially crafted HTTP Range headers, tCVE-2026-244307.5Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) disclose sensitive account credentials in cleartext within HTCVE-2026-244316.5Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) display stored user account passwords in plaintext within theCVE-2026-244324.3Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) lack cross-site request forgery (CSRF) protections on adminisCVE-2026-244335.4Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain a stored cross-site scripting vulnerability in the usCVE-2026-244346.5Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web maCVE-2026-244356.5Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) implement an insecure Cross-Origin Resource Sharing (CORS) poCVE-2026-244369.8Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) do not enforce rate limiting or account lockout mechanisms onCVE-2026-244375.5Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) serve sensitive administrative content without appropriate caCVE-2026-244396.5Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) fail to include the X-Content-Type-Options: nosniff response CVE-2026-244408.8Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenanceCVE-2026-244415.9Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-
CVE-2026-24429: Critical severity, CVSS 9.8 | Vulnix