CVE-2026-24099

MediumCVSS 5.1/10Last modified Sep 1, 2026

Description

Use after free for some Intel(R) PROSet/Wireless WiFi Software for Windows within Ring 0: Kernel may allow a denial of service. System software adversary with an unauthenticated user combined with a high complexity attack may enable denial of service. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (none) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.

Metrics

CVSS 3.1 5.1/10CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 11, 2026
Last modified
Sep 1, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-24104.3The Disable Admin Notices – Hide Dashboard Notifications plugin for WordPress is vulnerable to Cross-Site Request Forgery in all versions upCVE-2026-241019.8An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18_multi. When the condition is met, `s1_1` will be passed into suCVE-2026-241039.8A buffer overflow vulnerability was discovered in goform/formSetMacFilterCfg in Tenda AC15V1.0 V15.03.05.18_multi.CVE-2026-241059.8An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18_multi. The value of `v1` was not checked, potentially leadCVE-2026-241079.8An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Failure to validate the value of `usbPartitionName`, which is directly used in `doSCVE-2026-241089.8An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may exploit the vulnerability by controlling the value of `nptr`. When thCVE-2026-241099.8An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may exploit the vulnerability by controlling the value of `picName`. WhenCVE-2026-24116.5Zephyr's Bluetooth host declares a GATT characteristic as two consecutive attributes: a Characteristic Declaration whose permission is hard-CVE-2026-241109.8An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may send overly long `addDhcpRules` data. When these rules enter the `addCVE-2026-241119.8An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may exploit the vulnerability by specifying the value of `userInfo`. WhenCVE-2026-241129.8An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may exploit the vulnerability by specifying the value of `userInfo`. WhenCVE-2026-241139.8An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may exploit the vulnerability by controlling the value of `nptr`. When th
CVE-2026-24099: Medium severity, CVSS 5.1 | Vulnix