Description
Golioth Firmware SDK version 0.19.1 prior to 0.22.0, fixed in commit 0e788217, contain an out-of-bounds read due to improper null termination of a blockwise transfer path. blockwise_transfer_init() accepts a path whose length equals CONFIG_GOLIOTH_COAP_MAX_PATH_LEN and copies it using strncpy() without guaranteeing a trailing NUL byte, leaving ctx->path unterminated. A later strlen() on this buffer (in golioth_coap_client_get_internal()) can read past the end of the allocation, resulting in a crash/denial of service. The input is application-controlled (not network by default).
Metrics
CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:LWeakness enumeration
Affected software
No affected versions have been published.
Timeline
- Published
- Feb 26, 2026
- Last modified
- Jul 14, 2026
- NVD status
- Deferred