Description
In the Linux kernel, the following vulnerability has been resolved:
net/sched: act_gate: snapshot parameters with RCU on replace
The gate action can be replaced while the hrtimer callback or dump path is walking the schedule list.
Convert the parameters to an RCU-protected snapshot and swap updates under tcf_lock, freeing the previous snapshot via call_rcu(). When REPLACE omits the entry list, preserve the existing schedule so the effective state is unchanged.
Metrics
CVSS 3.1 7.8/10
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HAffected software
| Vendor | Product | Versions |
|---|---|---|
| Linux | Linux | >= a51c328df3106663879645680609eb49b3ff6444, < fc98fd8d214693be91253d9a88cdf8e5e143d124; >= a51c328df3106663879645680609eb49b3ff6444, < 8b1251bbf0f10ac745ed74bad4d3b433caa1eeae; >= a51c328df3106663879645680609eb49b3ff6444, < dfc314d7c767e350f78a46a8f8b134f80e8ad432; >= a51c328df3106663879645680609eb49b3ff6444, < 035d0d09d5ab3ed3e93d18cde2b562a6719eea23; >= a51c328df3106663879645680609eb49b3ff6444, < 04d75529dc0f9be78786162ebab7424af4644df2; >= a51c328df3106663879645680609eb49b3ff6444, < 58b162e318d0243ad2d7d92456c0873f2494c351; >= a51c328df3106663879645680609eb49b3ff6444, < 62413a9c3cb183afb9bb6e94dd68caf4e4145f4c |
| Linux | Linux | 5.8 |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 TM MFP - GNU/Linux subsystem | < * |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.7, < * |
References
- https://git.kernel.org/stable/c/035d0d09d5ab3ed3e93d18cde2b562a6719eea23Patch
- https://git.kernel.org/stable/c/04d75529dc0f9be78786162ebab7424af4644df2Patch
- https://git.kernel.org/stable/c/58b162e318d0243ad2d7d92456c0873f2494c351Patch
- https://git.kernel.org/stable/c/62413a9c3cb183afb9bb6e94dd68caf4e4145f4cPatch
- https://git.kernel.org/stable/c/8b1251bbf0f10ac745ed74bad4d3b433caa1eeaePatch
- https://git.kernel.org/stable/c/dfc314d7c767e350f78a46a8f8b134f80e8ad432Patch
- https://git.kernel.org/stable/c/fc98fd8d214693be91253d9a88cdf8e5e143d124Patch
- https://cert-portal.siemens.com/productcert/html/ssa-019113.html
- https://cert-portal.siemens.com/productcert/html/ssa-082556.html
- https://cert-portal.siemens.com/productcert/html/ssa-457936.html
- https://cert-portal.siemens.com/productcert/html/ssa-784472.html
Timeline
- Published
- Mar 18, 2026
- Last modified
- Nov 10, 2026
- NVD status
- Modified