CVE-2026-22265

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

Roxy-WI is a web interface for managing Haproxy, Nginx, Apache and Keepalived servers. Prior to 8.2.8.2, command injection vulnerability exists in the log viewing functionality that allows authenticated users to execute arbitrary system commands. The vulnerability is in app/modules/roxywi/logs.py line 87, where the grep parameter is used twice - once sanitized and once raw. This vulnerability is fixed in 8.2.8.2.

Metrics

CVSS 3.1 7.5/10CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 15, 2026
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-222668.8Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerabCVE-2026-222678.8Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attaCVE-2026-222686.5Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attaCVE-2026-222694.7Dell PowerProtect Data Manager, version(s) prior to 19.22, contain(s) an Improper Verification of Source of a Communication Channel vulnerabCVE-2026-22277.2A vulnerability was found in D-Link DCS-931L up to 1.13.0. Impacted is the function doSystem of the file /setSystemAdmin. Performing a manipCVE-2026-222706.7Dell PowerScale OneFS, versions prior to 9.10.1.6 and versions 9.11.0.0 through 9.12.0.1, contains an uncontrolled search path element vulneCVE-2026-222717.5Dell ECS, versions 3.8.1.0 through 3.8.1.7, and Dell ObjectScale versions prior to 4.2.0.0, contains a Cleartext Transmission of Sensitive ICVE-2026-222738.8Dell ECS, versions 3.8.1.0 through 3.8.1.7, and Dell ObjectScale versions prior to 4.2.0.0, contains an Use of Default Credentials vulnerabiCVE-2026-222746.5Dell ECS, versions 3.8.1.0 through 3.8.1.7, and Dell ObjectScale versions prior to 4.2.0.0, contains a Cleartext Transmission of Sensitive ICVE-2026-222754.4Dell ECS, versions 3.8.1.0 through 3.8.1.7, and Dell ObjectScale versions prior to 4.2.0.0, contains an Inclusion of Sensitive Information iCVE-2026-222765.5Dell ECS, versions 3.8.1.0 through 3.8.1.7, and Dell ObjectScale versions prior to 4.2.0.0, contains a Cleartext Storage of Sensitive InformCVE-2026-222777.8Dell UnityVSA, version(s) 5.4 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Inject
CVE-2026-22265: High severity, CVSS 7.5 | Vulnix