CVE-2025-8173

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

A vulnerability has been found in 1000 Projects ABC Courier Management System 1.0 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /Add_reciver.php. The manipulation of the argument reciver_name leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jul 25, 2025
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2025

CVE-2025-81746.3A vulnerability was found in code-projects Voting System 1.0 and classified as critical. Affected by this issue is some unknown functionalitCVE-2025-81757.5A vulnerability was found in D-Link DI-8400 16.07.26A1. It has been classified as problematic. This affects an unknown part of the file usb_CVE-2025-81767.8A vulnerability was found in LibTIFF up to 4.7.0. It has been declared as critical. This vulnerability affects the function get_histogram ofCVE-2025-81777.8A vulnerability was found in LibTIFF up to 4.7.0. It has been rated as critical. This issue affects the function setrow of the file tools/thCVE-2025-81788.8A vulnerability classified as critical has been found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /goform/RequestCVE-2025-81799.8A vulnerability classified as critical was found in PHPGurukul Local Services Search Engine Management System 2.1. Affected by this vulnerabCVE-2025-81808.8A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. Affected by this issue is the function formdeleteUsCVE-2025-81817.2A vulnerability, which was classified as critical, was found in TOTOLINK N600R and X2000R 1.0.0.1. This affects an unknown part of the file CVE-2025-81827.4A vulnerability has been found in Tenda AC18 15.03.05.19 and classified as problematic. This vulnerability affects unknown code of the file CVE-2025-81837.5NULL Pointer Dereference in µD3TN via non-singleton destination Endpoint Identifier allows remote attacker to reliably cause DoSCVE-2025-81849.8A vulnerability was found in D-Link DIR-513 up to 1.10 and classified as critical. This issue affects the function formSetWanL2TPcallback ofCVE-2025-81859.8A vulnerability was found in 1000 Projects ABC Courier Management System 1.0. It has been classified as critical. Affected is an unknown fun