CVE-2025-54795

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

Claude Code is an agentic coding tool. In versions below 1.0.20, an error in command parsing makes it possible to bypass the Claude Code confirmation prompt to trigger execution of an untrusted command. Reliably exploiting this requires the ability to add untrusted content into a Claude Code context window. This is fixed in version 1.0.20.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 5, 2025
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2025

CVE-2025-547967.5Copyparty is a portable file server. Versions prior to 1.18.9, the filter parameter for the "Recent Uploads" page allows arbitrary RegExes. CVE-2025-547985.3tmp is a temporary file and directory creator for node.js. In versions 0.2.3 and below, tmp is vulnerable to an arbitrary temporary file / dCVE-2025-547992.3Let's Encrypt client and ACME library written in Go (Lego). In versions 4.25.1 and below, the github.com/go-acme/lego/v4/acme/api package (tCVE-2025-54807.8Action1 Uncontrolled Search Path Element Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate priCVE-2025-548006.1Hydra is a continuous integration service for Nix based projects. Prior to commit dea1e16, a malicious package can introduce arbitrary JavaSCVE-2025-548017.5Fiber is an Express inspired web framework written in Go. In versions 2.52.8 and below, when using Fiber's Ctx.BodyParser to parse form dataCVE-2025-548029.8pyLoad is the free and open-source Download Manager written in pure Python. In versions 0.5.0b3.dev89 and below, there is an opportunity forCVE-2025-548037.5js-toml is a TOML parser for JavaScript, fully compliant with the TOML 1.0.0 Spec. In versions below 1.0.2, a prototype pollution vulnerabilCVE-2025-548046.5Russh is a Rust SSH client & server library. In versions 0.54.0 and below, the channel window adjust message of the SSH protocol is used to CVE-2025-548056.5When an iRule is configured on a virtual server via the declarative API, upon re-instantiation, the cleanup process can cause an increase inCVE-2025-548066.1GROWI v4.2.7 and earlier contains a cross-site scripting vulnerability in the page alert function. If a user accesses a crafted URL while lCVE-2025-548079.8The secret used for validating authentication tokens is hardcoded in device firmware for affected versions. An attacker who obtains the si
CVE-2025-54795: Critical severity, CVSS 9.8 | Vulnix