CVE-2025-4660

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

A remote code execution vulnerability exists in the Windows agent component of SecureConnector due to improper access controls on a named pipe. The pipe is accessible to the Everyone group and does not restrict remote connections, allowing any network-based attacker to connect without authentication. By interacting with this pipe, an attacker can redirect the agent to communicate with a rogue server that can issue commands via the SecureConnector Agent. 

This does not impact Linux or OSX Secure Connector.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
May 13, 2025
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2025

CVE-2025-466025.5Dell SupportAssist OS Recovery, versions prior to 5.5.15.0, contain an Insertion of Sensitive Information into Externally-Accessible File orCVE-2025-466037.5Dell CloudBoost Virtual Appliance, versions 19.13.0.0 and prior, contains an Improper Restriction of Excessive Authentication Attempts vulneCVE-2025-466057.2Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 8.4 through 8.5 contain a session fixatiCVE-2025-466067.2Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 8.4 through 8.5 contain an improper restCVE-2025-466077.2Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 8.4 through 8.5 contain an improper authCVE-2025-466087.2Dell Data Lakehouse, versions prior to 1.6.0.0, contain(s) an Improper Access Control vulnerability. A high privileged attacker with remote CVE-2025-46612.3A path transversal vulnerability in Brocade Fabric OS 9.1.0 through 9.2.2 could allow a local admin user to gain access to files outside tCVE-2025-466108.8ARTEC EMA Mail 6.92 allows CSRF.CVE-2025-466116.1Cross Site Scripting vulnerability in ARTEC EMA Mail v6.92 allows an attacker to execute arbitrary code via a crafted script.CVE-2025-466127.2The Panel Designer dashboard in Airleader Master and Easy before 6.36 allows remote attackers to execute arbitrary commands via a wizard/worCVE-2025-466137.5OpenPLC 3 through 64f9c11 has server.cpp Memory Corruption because a thread may access handleConnections arguments after the parent stack frCVE-2025-466143.3In Snowflake ODBC Driver before 3.7.0, in certain code paths, the Driver logged the whole SQL query at the INFO level, aka Insertion of Sens