Description
The affected devices contain a null pointer dereference vulnerability while processing specially crafted IPv4 requests. This could allow an attacker to cause denial of service condition. A manual restart is required to recover the system.
Metrics
CVSS 3.1 7.5/10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HWeakness enumeration
Affected software
Source: the vendor's advisory (CNA). NVD analysis pending.
| Vendor | Product | Versions |
|---|---|---|
| Siemens | IE/PB LINK HA (6GK1411-5BB00) | < * |
| Siemens | IE/PB link PN IO (6GK1411-5AB10) | < * |
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) | < V8.3 |
| Siemens | RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) | < V8.3 |
| Siemens | SCALANCE M804PB (6GK5804-0AP00-2AA2) | < V8.3 |
| Siemens | SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) | < V8.3 |
| Siemens | SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) | < V8.3 |
| Siemens | SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) | < V8.3 |
| Siemens | SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) | < V8.3 |
| Siemens | SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) | < V8.3 |
| Siemens | SCALANCE M874-2 (6GK5874-2AA00-2AA2) | < V8.3 |
| Siemens | SCALANCE M874-3 (6GK5874-3AA00-2AA2) | < V8.3 |
| Siemens | SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) | < V8.3 |
| Siemens | SCALANCE M876-3 (6GK5876-3AA02-2BA2) | < V8.3 |
| Siemens | SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) | < V8.3 |
| Siemens | SCALANCE M876-4 (6GK5876-4AA10-2BA2) | < V8.3 |
| Siemens | SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) | < V8.3 |
| Siemens | SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) | < V8.3 |
| Siemens | SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1) | < V8.3 |
| Siemens | SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1) | < V8.3 |
| Siemens | SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) | < V8.3 |
| Siemens | SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) | < V8.3 |
| Siemens | SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) | < V8.3 |
| Siemens | SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) | < V8.3 |
| Siemens | SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) | < V8.3 |
| Siemens | SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) | < V8.3 |
| Siemens | SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) | < V8.3 |
| Siemens | SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) | < V8.3 |
| Siemens | SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) | < V8.3 |
| Siemens | SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) | < V8.3 |
| Siemens | SCALANCE SC622-2C (6GK5622-2GS00-2AC2) | < V3.2 |
| Siemens | SCALANCE SC626-2C (6GK5626-2GS00-2AC2) | < V3.2 |
| Siemens | SCALANCE SC632-2C (6GK5632-2GS00-2AC2) | < V3.2 |
| Siemens | SCALANCE SC636-2C (6GK5636-2GS00-2AC2) | < V3.2 |
| Siemens | SCALANCE SC642-2C (6GK5642-2GS00-2AC2) | < V3.2 |
| Siemens | SCALANCE SC646-2C (6GK5646-2GS00-2AC2) | < V3.2 |
| Siemens | SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0) | < * |
| Siemens | SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0) | < * |
| Siemens | SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) | < * |
| Siemens | SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) | < * |
| Siemens | SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) | < * |
| Siemens | SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) | < * |
| Siemens | SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) | < V6.6.0 |
| Siemens | SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) | < V6.6.0 |
| Siemens | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) | < V6.6.0 |
| Siemens | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) | < V6.6.0 |
| Siemens | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) | < V6.6.0 |
| Siemens | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) | < V6.6.0 |
| Siemens | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) | < V6.6.0 |
| Siemens | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) | < V6.6.0 |
References
Timeline
- Published
- May 12, 2026
- Last modified
- Nov 10, 2026
- NVD status
- Awaiting Analysis