CVE-2025-40743

HighCVSS 8.3/10Last modified Jun 17, 2026

Description

A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.

Metrics

CVSS 3.1 8.3/10CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 12, 2025
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2025

CVE-2025-407447.5A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 11). Affected applications do not properly validate cCVE-2025-407453.7A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), SimcenteCVE-2025-407467.2A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.2). Affected products do not properly validate inputCVE-2025-40754.3A vulnerability was found in VMSMan up to 20250416. It has been rated as problematic. Affected by this issue is some unknown functionality oCVE-2025-407517.8A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.3). Affected SIMATIC RTLS Locating Manager Report ClCVE-2025-407526.2A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (CVE-2025-407536.2A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (CVE-2025-407558.8A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP1). Affected applications are vulnerable to SQL injection through geCVE-2025-407575.3A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC SCVE-2025-407588.7A vulnerability has been identified in Mendix SAML (Mendix 10.12 compatible) (All versions < V4.0.3), Mendix SAML (Mendix 10.21 compatible) CVE-2025-407597.8A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP CVE-2025-40766.3A vulnerability classified as critical has been found in LB-LINK BL-AC3600 up to 1.0.22. This affects the function easy_uci_set_option_strin
CVE-2025-40743: High severity, CVSS 8.3 | Vulnix