CVE-2025-40553

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

SolarWinds Web Help Desk was found to be susceptible to an untrusted data deserialization vulnerability that could lead to remote code execution, which would allow an attacker to run commands on the host machine. This could be exploited without authentication.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 28, 2026
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2025

CVE-2025-405549.8SolarWinds Web Help Desk was found to be susceptible to an authentication bypass vulnerability that, if exploited, could allow an attacker tCVE-2025-405554.7A vulnerability has been identified in APOGEE PXC+TALON TC Series (BACnet) (All versions). Affected devices start sending unsolicited BACnetCVE-2025-405566.5A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versCVE-2025-40567.5A flaw was found in GLib. A denial of service on Windows platforms may occur if an application attempts to spawn a program using long commanCVE-2025-405669.8A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 UpdateCVE-2025-405676.5A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All vCVE-2025-405684.3A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All vCVE-2025-405694.8A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All vCVE-2025-40575.5A flaw was found in ActiveMQ Artemis. The password generated by activemq-artemis-operator does not regenerate between separated CR dependencCVE-2025-405702.4A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V1CVE-2025-405712.2A vulnerability has been identified in Mendix OIDC SSO (Mendix 10.12 compatible) (All versions < V4.0.1), Mendix OIDC SSO (Mendix 9 compatibCVE-2025-405725.5A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly ass
CVE-2025-40553: Critical severity, CVSS 9.8 | Vulnix