CVE-2025-36607

HighCVSS 7.8/10Last modified Jun 17, 2026

Description

Dell Unity, version(s) 5.5 and prior, contain(s) an OS Command Injection Vulnerability in its svc_nas utility. An authenticated attacker could potentially exploit this vulnerability, escaping the restricted shell and execute arbitrary operating system commands with root privileges.

Metrics

CVSS 3.1 7.8/10CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 4, 2025
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2025

CVE-2025-366086.5Dell SmartFabric OS10 Software, versions prior to 10.6.0.5, contains an Improper Restriction of XML External Entity Reference vulnerability.CVE-2025-366097.8Dell SmartFabric OS10 Software, versions prior to 10.6.0.5, contains a Use of Hard-coded Password vulnerability. A low privileged attacker wCVE-2025-36616.4The SB Chart block plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the ‘className’ parameter in all versions up to, anCVE-2025-366117.8Dell Encryption and Dell Security Management Server, versions prior to 11.11.0, contain an Improper Link Resolution Before File Access ('LinCVE-2025-366127.8SupportAssist for Business PCs, version(s) 4.5.3 and prior, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attCVE-2025-366137.8SupportAssist for Home PCs versions 4.6.3 and prior and SupportAssist for Business PCs versions 4.5.3 and prior, contain(s) an Incorrect PriCVE-2025-36626.1The FancyBox for WordPress plugin before 3.3.6 does not escape captions and titles attributes before using them to populate galleries' captiCVE-2025-366254.3In Nessus versions prior to 10.8.4, a non-authenticated attacker could alter Nessus logging entries by manipulating http requests to the appCVE-2025-36638.2A vulnerability, which was classified as critical, has been found in TOTOLINK A3700R 9.1.2u.5822_B20200513. This issue affects the function CVE-2025-366307.1In Tenable Nessus versions prior to 10.8.5 on a Windows host, it was found that a non-administrative user could overwrite arbitrary local syCVE-2025-366317.8In Tenable Agent versions prior to 10.8.5 on a Windows host, it was found that a non-administrative user could overwrite arbitrary local sysCVE-2025-366327.8In Tenable Agent versions prior to 10.8.5 on a Windows host, it was found that a non-administrative user could execute code with SYSTEM priv
CVE-2025-36607: High severity, CVSS 7.8 | Vulnix