CVE-2025-34140

HighCVSS 8.7/10Last modified Jun 17, 2026

Description

An authorization bypass vulnerability exists in ETQ Reliance (legacy CG and NXG SaaS platforms). By appending a specific URI suffix to certain API endpoints, an unauthenticated attacker can bypass access control checks and retrieve limited sensitive resources. The root cause was a misconfiguration in API authorization logic, which has since been corrected in SE.2025.1 and 2025.1.2.

Metrics

CVSS 4.0 8.7/10CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jul 22, 2025
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2025

CVE-2025-341415.1A reflected cross-site scripting (XSS) vulnerability exists in ETQ Reliance CG (legacy) platform within the `SQLConverterServlet` component.CVE-2025-341426.9An XML External Entity (XXE) injection vulnerability exists in ETQ Reliance on the CG (legacy) platform within the `/resources/sessions/sso`CVE-2025-341439.3An authentication bypass vulnerability exists in ETQ Reliance on the CG (legacy) platform. The application allowed login as the privileged iCVE-2025-341467.0A prototype pollution vulnerability exists in @nyariv/sandboxjs versions <= 0.8.23, allowing attackers to inject arbitrary properties into OCVE-2025-341479.4An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02). When configurCVE-2025-341489.4An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02). When configurCVE-2025-341499.4A command injection vulnerability affects the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) during WPA2 configuration. The 'key'CVE-2025-34154.3Grafana is an open-source platform for monitoring and observability. The Grafana Alerting DingDing integration was not properly protected anCVE-2025-341509.4The PPPoE configuration interface of the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) is vulnerable to command injection via thCVE-2025-341519.4A command injection vulnerability exists in the 'passwd' parameter of the PPPoE setup process on the Shenzhen Aitemi M300 Wi-Fi Repeater (haCVE-2025-341529.4An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) via the 'time'CVE-2025-3415310.0Hyland OnBase versions prior to 17.0.2.87 (other versions may be affected) are vulnerable to unauthenticated remote code execution via insec
CVE-2025-34140: High severity, CVSS 8.7 | Vulnix