Description
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.
Metrics
CVSS 3.1 7.8/10
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HWeakness enumeration
Affected software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Automation License Manager V6.0 | < * |
| Siemens | Automation License Manager V6.2 | < V6.2 Upd3 |
| Siemens | CEMAT V10.0 | < * |
| Siemens | CP PtP Param configuring interface | < * |
| Siemens | Create MyConfig (CMC) | < V6.9 |
| Siemens | Energy Support Library (EnSL) | < * |
| Siemens | FM Configuration Package | < * |
| Siemens | Modular PID CTRL Tool | < * |
| Siemens | MultiFieldbus Configuration Tool (MFCT) | < V1.5.5.0 |
| Siemens | OpenPCS 7 V10.0 | < * |
| Siemens | OpenPCS 7 V9.1 | < * |
| Siemens | Siemens Network Planner (SINETPLAN) | < V2.0 SP2 |
| Siemens | SIMATIC Automation Tool | < V5.0 SP4 |
| Siemens | SIMATIC Automation Tool SDK Windows | < V5.0 SP4 |
| Siemens | SIMATIC BATCH V10.0 | < * |
| Siemens | SIMATIC BATCH V9.1 | < * |
| Siemens | SIMATIC Control Function Library (CFL) V1.x | < * |
| Siemens | SIMATIC Control Function Library (CFL) V2.x | < * |
| Siemens | SIMATIC Control Function Library (CFL) V3.x | < V3.1.0.2 |
| Siemens | SIMATIC Control Function Library (CFL) V4.x | < V4.1 |
| Siemens | SIMATIC D7-SYS | < V10.0 SP1 |
| Siemens | SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8) | < * |
| Siemens | SIMATIC eaSie Document Skills V26 | < * |
| Siemens | SIMATIC eaSie PCS 7 Skill Package V26 (6DL5424-0BX00-0AV8) | < * |
| Siemens | SIMATIC eaSie Workflow Skills V26 | < * |
| Siemens | SIMATIC Energy Suite V17 | < * |
| Siemens | SIMATIC Energy Suite V18 | < * |
| Siemens | SIMATIC Energy Suite V19 | < V19 Update 4 |
| Siemens | SIMATIC Logon V1.6 | < * |
| Siemens | SIMATIC Logon V2.0 | < V2.0 Upd3 |
| Siemens | SIMATIC Management Agent | < V9.1 SP1 Upd8 |
| Siemens | SIMATIC Management Console | < V9.1 SP1 Upd8 |
| Siemens | SIMATIC MTP CREATOR V2.x | < V2.1 |
| Siemens | SIMATIC MTP CREATOR V3.x | < * |
| Siemens | SIMATIC MTP CREATOR V4.x | < V4.1.0.1 |
| Siemens | SIMATIC MTP CREATOR V5.x | < V5.0.0.1 |
| Siemens | SIMATIC MTP Integrator V1.x | < * |
| Siemens | SIMATIC MTP Integrator V2.x | < * |
| Siemens | SIMATIC NET PC Software V16 | < * |
| Siemens | SIMATIC NET PC Software V17 | < * |
| Siemens | SIMATIC NET PC Software V18 | < * |
| Siemens | SIMATIC NET PC Software V19 | < * |
| Siemens | SIMATIC NET PC Software V20 | < V20.0 Update 1 |
| Siemens | SIMATIC ODK 1500S | < * |
| Siemens | SIMATIC PCS 7 Advanced Process Faceplates V9.1 | < V9.1 SP2 Upd4 |
| Siemens | SIMATIC PCS 7 Advanced Process Functions V2.1 | < * |
| Siemens | SIMATIC PCS 7 Advanced Process Functions V2.2 | < * |
| Siemens | SIMATIC PCS 7 Advanced Process Graphics V10.0 | < * |
| Siemens | SIMATIC PCS 7 Advanced Process Graphics V9.1 | < * |
| Siemens | SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0 | < * |
References
Timeline
- Published
- Aug 12, 2025
- Last modified
- Nov 10, 2026
- NVD status
- Deferred