CVE-2025-27580

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

NIH BRICS (aka Biomedical Research Informatics Computing System) through 14.0.0-67 generates predictable tokens (that depend on username, time, and the fixed 7Dl9#dj- string) and thus allows unauthenticated users with a Common Access Card (CAC) to escalate privileges and compromise any account, including administrators.

Metrics

CVSS 3.1 7.5/10CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 24, 2025
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2025

CVE-2025-275814.3NIH BRICS (aka Biomedical Research Informatics Computing System) through 14.0.0-67 allows users who lack the InET role to access the InET moCVE-2025-275827.6The Secure Password extension in One Identity Password Manager before 5.14.4 allows local privilege escalation. The issue arises from a flawCVE-2025-275839.1Incorrect access control in the component /rest/staffResource/findAllUsersAcrossOrg of Serosoft Solutions Pvt Ltd Academia Student InformatiCVE-2025-275845.4A stored cross-site scripting (XSS) vulnerability in Serosoft Solutions Pvt Ltd Academia Student Information System (SIS) EagleR v1.0.118 alCVE-2025-275855.4A stored cross-site scripting (XSS) vulnerability in Serosoft Solutions Pvt Ltd Academia Student Information System (SIS) EagleR v1.0.118 alCVE-2025-275875.3OpenSSL 3.0.0 through 3.3.2 on the PowerPC architecture is vulnerable to a Minerva attack, exploitable by measuring the time of signing of rCVE-2025-27597.8GStreamer Incorrect Permission Assignment Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate prCVE-2025-275909.8In oxidized-web (aka Oxidized Web) before 0.15.0, the RANCID migration page allows an unauthenticated user to gain control over the Linux usCVE-2025-275916.8A privilege escalation vulnerability existed in the Below service prior to v0.9.0 due to the creation of a world-writable directory at /var/CVE-2025-275939.3The product can be used to distribute malicious code using SDD Device Drivers due to missing download verification checks, leading to code eCVE-2025-275947.5The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device CVE-2025-275959.8The device uses a weak hashing alghorithm to create the password hash. Hence, a matching password can be easily calculated by an attacker. T
CVE-2025-27580: High severity, CVSS 7.5 | Vulnix