CVE-2025-27017

MediumCVSS 6.5/10Last modified Jun 17, 2026

Description

Apache NiFi 1.13.0 through 2.2.0 includes the username and password used to authenticate with MongoDB in the NiFi provenance events that MongoDB components generate during processing. An authorized user with read access to the provenance events of those processors may see the credentials information. Upgrading to Apache NiFi 2.3.0 is the recommended mitigation, which removes the credentials from provenance event records.

Metrics

CVSS 3.1 6.5/10CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 12, 2025
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2025

CVE-2025-270186.3Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Apache Airflow MySQL Provider. When uCVE-2025-270199.8Remote shell service (RSH) in Infinera MTC-9 version R22.1.1.0275 allows an attacker to utilize password-less user accounts and obtain sysCVE-2025-27026.3A vulnerability, which was classified as critical, has been found in Softwin WMX3 3.1. This issue affects the function ImageAdd of the file CVE-2025-270209.8Improper configuration of the SSH service in Infinera MTC-9 allows an unauthenticated attacker to execute arbitrary commands and access dataCVE-2025-270217.8The misconfiguration in the sudoers configuration of the operating system in Infinera G42 version R6.1.3 allows low privileged OS users to CVE-2025-270226.5A path traversal vulnerability of the WebGUI HTTP endpoint in Infinera G42 version R6.1.3 allows remote authenticated users to download allCVE-2025-270236.5Lack or insufficent input validation in WebGUI CLI web in Infinera G42 version R6.1.3 allows remote authenticated users to read all OS fileCVE-2025-270246.5Unrestricted access to OS file system in SFTP service in Infinera G42 version R6.1.3 allows remote authenticated users to read/write OS filCVE-2025-270258.8The target device exposes a service on a specific TCP port with a configured endpoint. The access to that endpoint is granted using a BasicCVE-2025-270264.9A missing double-check feature in the WebGUI for CLI deactivation in Infinera G42 version R6.1.3 allows an authenticated administrator to mCVE-2025-270274.1A user with vpuser credentials that opens an SSH connection to the device, gets a restricted shell rbash that allows only a small list of alCVE-2025-270286.8The Linux deprivileged user vpuser in Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) can read the entire file system content, includin
CVE-2025-27017: Medium severity, CVSS 6.5 | Vulnix