CVE-2024-39345

HighCVSS 7.2/10Last modified Jun 17, 2026

Description

AdTran 834-5 HDC17600021F1 (SmartOS 11.1.1.1) devices enable the SSH service by default and have a hidden, undocumented, hard-coded support account whose password is based on the devices MAC address. All of the devices internet interfaces share a similar MAC address that only varies in their final octet. This allows network-adjacent attackers to derive the support user's SSH password by decrementing the final octet of the connected gateway address or via the BSSID. An attacker can then execute arbitrary OS commands with root-level privileges. NOTE: The vendor states that there is no intended functionality allowing an attacker to execute arbitrary OS Commands with root-level privileges. The vendor also states that this issue was fixed in SmartOS 12.5.5.1.

Metrics

CVSS 3.1 7.2/10CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jul 24, 2024
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2024

CVE-2024-393475.9Incorrect default permissions vulnerability in firewall functionality in Synology Router Manager (SRM) before 1.2.5-8227-11 and 1.3.1-9346-8CVE-2024-393487.5Download of code without integrity check vulnerability in AirPrint functionality in Synology Router Manager (SRM) before 1.2.5-8227-11 and 1CVE-2024-393499.8A vulnerability regarding buffer copy without checking size of input ('Classic Buffer Overflow') is found in the libjansson component and itCVE-2024-39356.5In Eclipse Mosquito, versions from 2.0.0 through 2.0.18, if a Mosquitto broker is configured to create an outgoing bridge connection, and thCVE-2024-393507.5A vulnerability regarding authentication bypass by spoofing is found in the RTSP functionality. This allows man-in-the-middle attackers to oCVE-2024-393517.2A vulnerability regarding improper neutralization of special elements used in an OS command ('OS Command Injection') is found in the NTP conCVE-2024-393524.9A vulnerability regarding incorrect authorization is found in the firmware upgrade functionality. This allows remote authenticated users witCVE-2024-393532.7Mattermost versions 9.5.x <= 9.5.5 and 9.8.0 fail to sanitize the RemoteClusterFrame payloads before audit logging them which allows a high CVE-2024-393547.8If an attacker tricks a valid user into running Delta Electronics DIAScreen with a file containing malicious code, a stack-based buffer overCVE-2024-393556.5Improper handling of physical or environmental conditions in some Intel(R) Processors may allow an authenticated user to enable denial of seCVE-2024-393567.4NULL pointer dereference in some Intel(R) PROSet/Wireless WiFi and Killerâ„¢ WiFi software for Windows before version 23.80 may allow an unaCVE-2024-393577.2A stack-based buffer overflow vulnerability exists in the wireless.cgi SetName() functionality of Wavlink AC3000 M33A8.V5030.210505. A speci
CVE-2024-39345: High severity, CVSS 7.2 | Vulnix