CVE-2024-25126

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

Rack is a modular Ruby web server interface. Carefully crafted content type headers can cause Rack’s media type parser to take much longer than expected, leading to a possible denial of service vulnerability (ReDos 2nd degree polynomial). This vulnerability is patched in 3.0.9.1 and 2.2.8.1.

Metrics

CVSS 3.1 7.5/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 29, 2024
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2024

CVE-2024-251289.1Flask-AppBuilder is an application development framework, built on top of Flask. When Flask-AppBuilder is set to AUTH_TYPE AUTH_OID, it alloCVE-2024-251295.5The CodeQL CLI repo holds binaries for the CodeQL command line interface (CLI). Prior to version 2.16.3, an XML parser used by the CodeQL CLCVE-2024-25135.4The WP Chat App plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the 'imageAlt' block attribute in all versions up to, CVE-2024-251306.5Tuleap is an open source suite to improve management of software developments and collaboration. Prior to version 15.5.99.76 of Tuleap CommuCVE-2024-251318.8A flaw was found in the MustGather.managed.openshift.io Custom Defined Resource (CRD) of OpenShift Dedicated. A non-privileged user on the cCVE-2024-251324.3A flaw was found in the Hive hibernation controller component of OpenShift Dedicated. The ClusterDeployment.hive.openshift.io/v1 resource caCVE-2024-251338.8A flaw was found in the Hive ClusterDeployments resource in OpenShift Dedicated. In certain conditions, this issue may allow a developer accCVE-2024-251367.5There is a function in AutomationDirect C-MORE EA9 HMI that allows an attacker to send a relative path in the URL without proper sanitizing CVE-2024-251374.3In AutomationDirect C-MORE EA9 HMI there is a program that copies a buffer of a size controlled by the user into a limited sized buffer on tCVE-2024-251386.5In AutomationDirect C-MORE EA9 HMI, credentials used by the platform are stored as plain text on the device.CVE-2024-2513910.0In TP-Link Omada er605 1.0.1 through (v2.6) 2.2.3, a cloud-brd binary is susceptible to an integer overflow that leads to a heap-based buffeCVE-2024-25149.8A vulnerability classified as critical was found in MAGESH-K21 Online-College-Event-Hall-Reservation-System 1.0. Affected by this vulnerabil
CVE-2024-25126: High severity, CVSS 7.5 | Vulnix