CVE-2024-22041

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems improperly handles memory buffers when parsing X.509 certificates. This could allow an unauthenticated remote attacker to crash the network service.

Metrics

CVSS 3.1 7.5/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 12, 2024
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2024

CVE-2024-220427.8A vulnerability has been identified in Unicam FX (All versions). The windows installer agent used in affected product contains incorrect useCVE-2024-220435.5A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.251), Parasolid V35.1 (All versions < V35.1.170). The affected CVE-2024-220447.5A vulnerability has been identified in SENTRON 3KC ATC6 Expansion Module Ethernet (3KC9000-8TL75) (All versions). Affected devices expose anCVE-2024-220456.5A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.1 SP1). The product places sensitive information intoCVE-2024-220473.1A race condition exists in Audited 4.0.0 to 5.3.3 that can result in an authenticated user to cause audit log entries to be attributed to anCVE-2024-220486.1govuk_tech_docs versions from 2.0.2 to before 3.3.1 are vulnerable to a cross-site scripting vulnerability. Malicious JavaScript may be execCVE-2024-220495.3httparty before 0.21.0 is vulnerable to an assumed-immutable web parameter vulnerability. A remote and unauthenticated attacker can provide CVE-2024-220507.5Path traversal in the static file service in Iodine less than 0.7.33 allows an unauthenticated, remote attacker to read files outside the puCVE-2024-220519.8CommonMarker versions prior to 0.23.4 are at risk of an integer overflow vulnerability. This vulnerability can result in possibly unauthentiCVE-2024-220527.5A null pointer dereference vulnerability in IPSec component of Ivanti Connect Secure (9.x, 22.x) and Ivanti Policy Secure allows an unauthenCVE-2024-220538.2A heap overflow vulnerability in IPSec component of Ivanti Connect Secure (9.x 22.x) and Ivanti Policy Secure allows an unauthenticated malCVE-2024-220547.5A malformed discovery packet sent by a malicious actor with preexisting access to the network could interrupt the functionality of device ma
CVE-2024-22041: High severity, CVSS 7.5 | Vulnix