CVE-2024-20109

MediumCVSS 6.7/10Last modified Jun 17, 2026

Description

In ccu, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS09065928; Issue ID: MSV-1763.

Metrics

CVSS 3.1 6.7/10CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

VendorProductVersions
MediaTek, Inc.MT6765, MT6768, MT6833, MT6853, MT6873, MT6877, MT6885, MT6893, MT8188, MT8195Android 12.0, 13.0, 14.0, 15.0
mediatekmt6765<= *
mediatekmt6768<= *
mediatekmt6833<= *
mediatekmt6853<= *
mediatekmt6873<= *
mediatekmt6877<= *
mediatekmt6885<= *
mediatekmt6893<= *
mediatekmt8188<= *
mediatekmt8195<= *
googleandroid12.0; 13.0; 14.0; 15.0

References

Timeline

Published
Nov 4, 2024
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2024

CVE-2024-20119.8A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that if exploited will generally lead to a denial of service but canCVE-2024-201106.7In ccu, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System CVE-2024-201116.7In ccu, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System CVE-2024-201124.4In isp, there is a possible out of bounds read due to a missing bounds check. This could lead to local denial of service with System executiCVE-2024-201136.7In ccu, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System CVE-2024-201146.7In ccu, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System CVE-2024-201156.7In ccu, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System CVE-2024-201164.4In cmdq, there is a possible out of bounds read due to a missing bounds check. This could lead to local information disclosure with System eCVE-2024-201174.4In vdec, there is a possible out of bounds read due to improper structure design. This could lead to local information disclosure with SysteCVE-2024-201186.7In mms, there is a possible out of bounds write due to an incorrect bounds check. This could lead to local escalation of privilege with SystCVE-2024-201196.7In mms, there is a possible out of bounds write due to an incorrect bounds check. This could lead to local escalation of privilege with SystCVE-2024-20129.8vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway that if exploited an attacker could use to allow unintended commands or cod
CVE-2024-20109: Medium severity, CVSS 6.7 | Vulnix