CVE-2022-3007

HighCVSS 8.1/10Last modified Jun 17, 2026

Description

The vulnerability exists in Syska SW100 Smartwatch due to an improper implementation and/or configuration of Nordic Device Firmware Update (DFU) which is used for performing Over-The-Air (OTA) firmware updates on the Bluetooth Low Energy (BLE) devices. An unauthenticated attacker could exploit this vulnerability by setting arbitrary values to handle on the vulnerable device over Bluetooth.

Successful exploitation of this vulnerability could allow the attacker to perform firmware update, device reboot or data manipulation on the target device.

Metrics

CVSS 3.1 8.1/10CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Oct 31, 2023
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2022

CVE-2022-300725.4WBCE CMS 1.5.2 is vulnerable to Cross Site Scripting (XSS) via \admin\pages\sections_save.php namesection2 parameters.CVE-2022-300735.4WBCE CMS 1.5.2 is vulnerable to Cross Site Scripting (XSS) via /admin/users/save.php.CVE-2022-300758.8In TP-Link Router AX50 firmware 210730 and older, import of a malicious backup file via web interface can lead to remote code execution due CVE-2022-300765.3ENTAB ERP 1.0 allows attackers to discover users' full names via a brute force attack with a series of student usernames such as s10000 throCVE-2022-300788.8NETGEAR R6200_V2 firmware versions through R6200v2-V1.0.3.12_10.1.11 and R6300_V2 firmware versions through R6300v2-V1.0.4.52_10.0.93 allow CVE-2022-300798.8Command injection vulnerability was discovered in Netgear R6200 v2 firmware through R6200v2-V1.0.3.12 via binary /sbin/acos_service that couCVE-2022-30088.8The tinygltf library uses the C library function wordexp() to perform file path expansion on untrusted paths that are provided from the inpuCVE-2022-300839.8EllieGrid Android Application version 3.4.1 is vulnerable to Code Injection. The application appears to evaluate user input as code (remote)CVE-2022-30107.5The Priva TopControl Suite contains predictable credentials for the SSH service, based on the Serial number. Which makes it possible for an CVE-2022-301059.8In Belkin N300 Firmware 1.00.08, the script located at /setting_hidden.asp, which is accessible before and after configuring the device, exhCVE-2022-301106.1The file preview functionality in Jirafeau < 4.4.0, which is enabled by default, could be exploited for cross site scripting. An attacker coCVE-2022-301116.8Due to the use of an insecure algorithm for rolling codes in MCK Smartlock 1.0, allows attackers to unlock the mechanism via replay attacks.
CVE-2022-3007: High severity, CVSS 8.1 | Vulnix