Description
The APDFL.dll in Siemens JT2Go prior to V13.3.0.5 and Siemens Teamcenter Visualization prior to V14.0.0.2 contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
Metrics
CVSS 3.1 7.8/10
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:HWeakness enumeration
Affected software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | JT2Go | >= unspecified, < V13.3.0.5 |
| Siemens | Teamcenter Visualization V13.3 | >= unspecified, < V13.3.0.5 |
| Siemens | Teamcenter Visualization V14.0 | >= unspecified, < V14.0.0.2 |
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-829738.pdfVendor Advisory
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-195-07Third Party Advisory, US Government Resource
- https://cert-portal.siemens.com/productcert/pdf/ssa-829738.pdfVendor Advisory
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-195-07Third Party Advisory, US Government Resource
Timeline
- Published
- Oct 20, 2022
- Last modified
- Jun 17, 2026
- NVD status
- Modified